Hanna Instruments® Model 9829 pH/ORP/Conductivity/Dissolved Oxygen Meter
Combining a multiparameter probe with field-replaceable sensors, this versatile, waterproof meter measures pH, ORP, conductivity, dissolved oxygen, temperature, resistivity, TDS, salinity, seawater specific gravity, and atmospheric pressure (measured for dissolved oxygen compensation).
Range: Temperature, 23.00°F to 131.00°F (-5.00°C to 55.00°C, 268.15 K to 328.15 K); pH, 0.00 to 14.00 pH; ORP, ±2000.0 mV; Dissolved Oxygen, 0.0 to 500.0%, 0.00 to 50.00 mg/L; Conductivity, 0 to 200 mS/cm (absolute EC up to 400 mS/cm); Resistivity, 0 to 999999 Ω•cm, 0 to 1000.0 kΩ•cm, 0 to 1.0000 MΩ•cm; TDS, 0 to 400000 mg/L or ppm (maximum value depends on the TDS factor); Salinity, 0.00 to 70.00 PSU (extended Practical Salinity Scale); Seawater Sigma, 0.0 to 50.0; Atmospheric Pressure, 450 to 850 mmHg, 17.72 to 33.46 inHg, 600.0 to 1133.2 mbar, 8.702 to 16.436 psi, 0.5921 to 1.1184 atm, 60.00 to 113.32 kPa. Resolution: Temperature, 0.01°F (0.01 °C, 0.01 K); pH, 0.01 pH; ORP, 0.1 mV; Dissolved Oxygen, 0.1%, 0.01 mg/L; Conductivity – Manual, 1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm; Automatic, 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic mS/cm, 0.001 mS/cm from 0.000 to 9.999 mS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Resistivity, Depending on resistivity reading; TDS – Manual, 1 mg/L (ppm), 0.001 g/L (ppt), 0.01 g/L (ppt), 0.1 g/L (ppt), 1 g/L (ppt); Automatic, 1 mg/L (ppm) from 0 to 9999 mg/L (ppm), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Automatic g/L (ppt), 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Salinity, 0.01 PSU; Seawater Sigma, 0.1; Atmospheric Pressure, 0.1 mmHg, 0.01 inHg, 0.1 mbar, 0.001 psi, 0.0001 atm, 0.01 kPa. Accuracy: Temperature, ±0.27°F (±0.15°C, ±0.15 K); pH, ±0.02 pH; ORP, ±1.0 mV; Dissolved Oxygen, 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading; Conductivity, ±1% of reading or ±1 µS/cm whichever is greater; TDS, ±1% of reading or ±1 mg/L (ppm) whichever is greater; Salinity, ±2% of reading or ±0.01 PSU whichever is greater; Seawater Sigma, ±1; Atmospheric Pressure, ±3 mmHg within ±15°C from the temperature during calibration. Temperature Compensation: Automatic from 23°F to 131°F (-5°C to 55°C). Waterproof Protection: Meter, IP67; Probe, IP68. Battery: 4 rechargeable C cell Ni-MH batteries (included) or 4 alkaline C cell batteries (not included). Dimensions: 8.7˝ x 4.5˝ x 2.2˝. Weight: 26.5 oz.
Hanna Instruments® Model 9829 pH/ORP/Conductivity/Dissolved Oxygen Meter
Combining a multiparameter probe with field-replaceable sensors, this versatile, waterproof meter measures pH, ORP, conductivity, dissolved oxygen, temperature, resistivity, TDS, salinity, seawater specific gravity, and atmospheric pressure (measured for dissolved oxygen compensation).
Product Description
Range: Temperature, 23.00°F to 131.00°F (-5.00°C to 55.00°C, 268.15 K to 328.15 K); pH, 0.00 to 14.00 pH; ORP, ±2000.0 mV; Dissolved Oxygen, 0.0 to 500.0%, 0.00 to 50.00 mg/L; Conductivity, 0 to 200 mS/cm (absolute EC up to 400 mS/cm); Resistivity, 0 to 999999 Ω•cm, 0 to 1000.0 kΩ•cm, 0 to 1.0000 MΩ•cm; TDS, 0 to 400000 mg/L or ppm (maximum value depends on the TDS factor); Salinity, 0.00 to 70.00 PSU (extended Practical Salinity Scale); Seawater Sigma, 0.0 to 50.0; Atmospheric Pressure, 450 to 850 mmHg, 17.72 to 33.46 inHg, 600.0 to 1133.2 mbar, 8.702 to 16.436 psi, 0.5921 to 1.1184 atm, 60.00 to 113.32 kPa. Resolution: Temperature, 0.01°F (0.01 °C, 0.01 K); pH, 0.01 pH; ORP, 0.1 mV; Dissolved Oxygen, 0.1%, 0.01 mg/L; Conductivity – Manual, 1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm; Automatic, 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic mS/cm, 0.001 mS/cm from 0.000 to 9.999 mS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Resistivity, Depending on resistivity reading; TDS – Manual, 1 mg/L (ppm), 0.001 g/L (ppt), 0.01 g/L (ppt), 0.1 g/L (ppt), 1 g/L (ppt); Automatic, 1 mg/L (ppm) from 0 to 9999 mg/L (ppm), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Automatic g/L (ppt), 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Salinity, 0.01 PSU; Seawater Sigma, 0.1; Atmospheric Pressure, 0.1 mmHg, 0.01 inHg, 0.1 mbar, 0.001 psi, 0.0001 atm, 0.01 kPa. Accuracy: Temperature, ±0.27°F (±0.15°C, ±0.15 K); pH, ±0.02 pH; ORP, ±1.0 mV; Dissolved Oxygen, 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading; Conductivity, ±1% of reading or ±1 µS/cm whichever is greater; TDS, ±1% of reading or ±1 mg/L (ppm) whichever is greater; Salinity, ±2% of reading or ±0.01 PSU whichever is greater; Seawater Sigma, ±1; Atmospheric Pressure, ±3 mmHg within ±15°C from the temperature during calibration. Temperature Compensation: Automatic from 23°F to 131°F (-5°C to 55°C). Waterproof Protection: Meter, IP67; Probe, IP68. Battery: 4 rechargeable C cell Ni-MH batteries (included) or 4 alkaline C cell batteries (not included). Dimensions: 8.7˝ x 4.5˝ x 2.2˝. Weight: 26.5 oz.
Additional Information
Hanna
HI 9829-00041
41112304