LaMotte Ratiometric Turbidity Meter Model 2020i
Thanks to the infrared lamp in this meter, it is ideal for environmental analysis. The multi-detector optical configuration assures long-term stability and minimizes stray light and color interference.
Unit of Measure – Ratiometric: FNRU, NTU, ASBC, EBC. Nephelometric: FNU, NTU, ASBC, EBC. Attenuation: FAU, NTU, ASBC, EBC. Range – Ratiometric: 0-1,000 FNRU; 0-17,500 ASBC; 0-250 EBC. Nephelometric: 0-100 FNU; 0-1,750 ASBC; 0-25 EBC. Attenuation: 0-2,000 FAU; 0-35,000 ASBC; 0-500 EBC. Resolution – Ratiometric: 0–10.99 FNRU: 0.01; 11.0–109.9 FNRU: 0.1; 110–1000 FNRU: 1. Nephelometric: 0–10.99 FNU: 0.01; 11.0–100.0 FNU: 0.1. Attenuation: 0–2000 FAU: 1. Accuracy – Ratiometric: 0-2.5 FNRU: ±0.05; 2.5-100 FNRU: ±2%; 100-1000 FNRU: ±3%. Nephelometric: 0-2.5 FNU: ±0.05; 2.5-100 FNU: ±2%. Attenuation: 0-2000 FAU: ±10 FAU or 6%, whichever is greater. Detection Limit – Ratiometric: 0.05 FNRU. Nephelometric: 0.05 FNU. Attenuation: 10 FAU. Reproducibility – Ratiometric: 0.02 FNRU or 1%. Nephelometric: 0.02 FNU or 1%. Attenuation: 1%. Range Selection – Automatic. Light Source – IR LED 860 nm ±10 nm, spectral bandwidth with 50 nm. Detector – Photodiode, centered at 90° and 180°.
LaMotte
1974-i
63739547077
041104007
LaMotte Ratiometric Turbidity Meter Model 2020i
LaMotte Ratiometric Turbidity Meter Model 2020i
Thanks to the infrared lamp in this meter, it is ideal for environmental analysis. The multi-detector optical configuration assures long-term stability and minimizes stray light and color interference.
Product Description
Unit of Measure – Ratiometric: FNRU, NTU, ASBC, EBC. Nephelometric: FNU, NTU, ASBC, EBC. Attenuation: FAU, NTU, ASBC, EBC. Range – Ratiometric: 0-1,000 FNRU; 0-17,500 ASBC; 0-250 EBC. Nephelometric: 0-100 FNU; 0-1,750 ASBC; 0-25 EBC. Attenuation: 0-2,000 FAU; 0-35,000 ASBC; 0-500 EBC. Resolution – Ratiometric: 0–10.99 FNRU: 0.01; 11.0–109.9 FNRU: 0.1; 110–1000 FNRU: 1. Nephelometric: 0–10.99 FNU: 0.01; 11.0–100.0 FNU: 0.1. Attenuation: 0–2000 FAU: 1. Accuracy – Ratiometric: 0-2.5 FNRU: ±0.05; 2.5-100 FNRU: ±2%; 100-1000 FNRU: ±3%. Nephelometric: 0-2.5 FNU: ±0.05; 2.5-100 FNU: ±2%. Attenuation: 0-2000 FAU: ±10 FAU or 6%, whichever is greater. Detection Limit – Ratiometric: 0.05 FNRU. Nephelometric: 0.05 FNU. Attenuation: 10 FAU. Reproducibility – Ratiometric: 0.02 FNRU or 1%. Nephelometric: 0.02 FNU or 1%. Attenuation: 1%. Range Selection – Automatic. Light Source – IR LED 860 nm ±10 nm, spectral bandwidth with 50 nm. Detector – Photodiode, centered at 90° and 180°.
Additional Information
LaMotte
1974-i
63739547077
041104007